# blueprints/automation/slimme_warmtebron_sturing.yaml
|
||
|
||
blueprint:
|
||
name: Slimme Warmtebron Sturing (Airco / Gas + Koeling)
|
||
description: >
|
||
Schakel automatisch tussen airco (warmtepomp) en gasverwarming op basis van
|
||
nettovermogen en een zelf te kiezen temperatuursensor. Ondersteunt verwarmen,
|
||
koelen én automatische seizoenswisseling. Inclusief hysterese.
|
||
domain: automation
|
||
input:
|
||
|
||
# ── Bedrijfsmodus ──────────────────────────────────────────────────────────
|
||
operation_mode:
|
||
name: Bedrijfsmodus
|
||
description: >
|
||
Verwarmen: alleen verwarmingslogica actief.
|
||
Koelen: alleen koellogica actief.
|
||
Automatisch: verwarm als temp onder doel, koel als temp boven doel.
|
||
default: "auto"
|
||
selector:
|
||
select:
|
||
options:
|
||
- label: "🔥 Verwarmen"
|
||
value: "heating"
|
||
- label: "❄️ Koelen"
|
||
value: "cooling"
|
||
- label: "🔄 Automatisch"
|
||
value: "auto"
|
||
|
||
# ── Vermogen ───────────────────────────────────────────────────────────────
|
||
power_sensor:
|
||
name: Nettovermogen sensor
|
||
description: >
|
||
Sensor in Watt. Negatief = injectie naar net (zonne-overschot),
|
||
positief = afname van net.
|
||
selector:
|
||
entity:
|
||
domain: sensor
|
||
device_class: power
|
||
|
||
solar_surplus_threshold:
|
||
name: Zonne-overschot drempel – verwarmen (W)
|
||
description: >
|
||
Minimale injectie (absoluut) vooraleer de airco als warmtebron gekozen
|
||
wordt boven gas. Bv. 500 = airco start bij ≥ 500 W injectie.
|
||
default: 500
|
||
selector:
|
||
number:
|
||
min: 0
|
||
max: 5000
|
||
step: 50
|
||
unit_of_measurement: "W"
|
||
mode: slider
|
||
|
||
grid_threshold:
|
||
name: Netstroom drempel → gasverwarming (W)
|
||
description: >
|
||
Afname boven deze waarde schakelt over naar gas (goedkoper bij hoge
|
||
elektriciteitsprijs). Stem af op actuele gas/elektriciteitsverhouding.
|
||
default: 1000
|
||
selector:
|
||
number:
|
||
min: 0
|
||
max: 5000
|
||
step: 50
|
||
unit_of_measurement: "W"
|
||
mode: slider
|
||
|
||
solar_surplus_threshold_cooling:
|
||
name: Zonne-overschot drempel – koelen (W)
|
||
description: >
|
||
Minimale injectie om de airco in koelmodus te starten. Zet lager dan
|
||
de verwarmingsdrempel want koelen verbruikt doorgaans minder.
|
||
Bv. 300 W.
|
||
default: 300
|
||
selector:
|
||
number:
|
||
min: 0
|
||
max: 5000
|
||
step: 50
|
||
unit_of_measurement: "W"
|
||
mode: slider
|
||
|
||
cool_on_grid:
|
||
name: Koelen ook bij netstroom?
|
||
description: >
|
||
Er is geen alternatief voor de airco bij koeling. Als dit aan staat,
|
||
koelt de airco ook wanneer er stroom van het net wordt afgenomen.
|
||
Zet uit als je stroomkosten wilt vermijden en hitte verdraagbaar is.
|
||
default: true
|
||
selector:
|
||
boolean:
|
||
|
||
cool_grid_threshold:
|
||
name: Max. netstroom bij koelen (W)
|
||
description: >
|
||
Enkel zichtbaar als "Koelen ook bij netstroom" aan staat. Boven deze
|
||
netstroom wordt koeling onderdrukt (piekuur-logica). 0 = geen limiet.
|
||
default: 2000
|
||
selector:
|
||
number:
|
||
min: 0
|
||
max: 6000
|
||
step: 50
|
||
unit_of_measurement: "W"
|
||
mode: slider
|
||
|
||
# ── Temperatuur ────────────────────────────────────────────────────────────
|
||
temperature_sensor:
|
||
name: Temperatuursensor (referentie)
|
||
description: >
|
||
Gebruik bij voorkeur de Tado wandthermostaat — de airco-sensor leest
|
||
doorgaans 1–2 °C hoger door stralingswarmte van de unit.
|
||
selector:
|
||
entity:
|
||
domain: sensor
|
||
device_class: temperature
|
||
|
||
target_temperature:
|
||
name: Doeltemperatuur (°C)
|
||
default: 20
|
||
selector:
|
||
number:
|
||
min: 10
|
||
max: 30
|
||
step: 0.5
|
||
unit_of_measurement: "°C"
|
||
mode: slider
|
||
|
||
hysteresis:
|
||
name: Hysterese (°C)
|
||
description: >
|
||
Marge rond de doeltemperatuur om pendelen te voorkomen.
|
||
Verwarming start onder (doel − hysterese), koeling boven (doel + hysterese).
|
||
default: 0.5
|
||
selector:
|
||
number:
|
||
min: 0.1
|
||
max: 3
|
||
step: 0.1
|
||
unit_of_measurement: "°C"
|
||
|
||
# ── Klimaatentiteiten ──────────────────────────────────────────────────────
|
||
airco_climate:
|
||
name: Airco (climate entiteit)
|
||
selector:
|
||
entity:
|
||
domain: climate
|
||
|
||
tado_climate:
|
||
name: Tado gasverwarming (climate entiteit)
|
||
selector:
|
||
entity:
|
||
domain: climate
|
||
|
||
tado_off_temperature:
|
||
name: Tado rusttemperatuur (°C)
|
||
description: >
|
||
Temperatuur die Tado krijgt wanneer gas niet nodig is (vorstbeveiliging).
|
||
Tado gaat zelden echt "uit" — stel dit laag in (bv. 5 °C).
|
||
default: 5
|
||
selector:
|
||
number:
|
||
min: 5
|
||
max: 15
|
||
step: 0.5
|
||
unit_of_measurement: "°C"
|
||
|
||
# ── Variabelen ─────────────────────────────────────────────────────────────────
|
||
variables:
|
||
_power_sensor: !input power_sensor
|
||
_temp_sensor: !input temperature_sensor
|
||
_solar_heat: !input solar_surplus_threshold
|
||
_grid_thresh: !input grid_threshold
|
||
_solar_cool: !input solar_surplus_threshold_cooling
|
||
_cool_on_grid: !input cool_on_grid
|
||
_cool_grid_max: !input cool_grid_threshold
|
||
_target: !input target_temperature
|
||
_hyst: !input hysteresis
|
||
_tado_off: !input tado_off_temperature
|
||
_mode: !input operation_mode
|
||
|
||
current_power: "{{ states(_power_sensor) | float(0) }}"
|
||
current_temp: "{{ states(_temp_sensor) | float(0) }}"
|
||
|
||
# Verwarmingslogica
|
||
needs_heat: "{{ current_temp < (_target | float - _hyst | float) }}"
|
||
solar_heat_ok: "{{ current_power <= (_solar_heat | float * -1) }}"
|
||
grid_high: "{{ current_power >= (_grid_thresh | float) }}"
|
||
|
||
# Koelingslogica
|
||
needs_cool: "{{ current_temp > (_target | float + _hyst | float) }}"
|
||
solar_cool_ok: "{{ current_power <= (_solar_cool | float * -1) }}"
|
||
grid_cool_ok: >
|
||
{{ _cool_on_grid and
|
||
(_cool_grid_max == 0 or current_power < _cool_grid_max | float) }}
|
||
|
||
# Gecombineerde modus checks
|
||
do_heat: >
|
||
{{ ((_mode == 'heating') or (_mode == 'auto' and needs_heat))
|
||
and not needs_cool }}
|
||
do_cool: >
|
||
{{ ((_mode == 'cooling') or (_mode == 'auto' and needs_cool))
|
||
and not needs_heat }}
|
||
at_target: >
|
||
{{ current_temp >= (_target | float - _hyst | float) and
|
||
current_temp <= (_target | float + _hyst | float) }}
|
||
|
||
# ── Trigger ────────────────────────────────────────────────────────────────────
|
||
trigger:
|
||
- platform: time_pattern
|
||
minutes: "/5"
|
||
- platform: state
|
||
entity_id: !input temperature_sensor
|
||
|
||
mode: single
|
||
max_exceeded: silent
|
||
|
||
# ── Acties ─────────────────────────────────────────────────────────────────────
|
||
action:
|
||
- choose:
|
||
|
||
# ── VERWARMEN ─────────────────────────────────────────────────────────────
|
||
|
||
# V1: Genoeg zonne-overschot → airco verwarmt, Tado op rust
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ do_heat and solar_heat_ok }}"
|
||
sequence:
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "heat"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
temperature: "{{ _target }}"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input tado_climate
|
||
data:
|
||
temperature: "{{ _tado_off }}"
|
||
|
||
# V2: Te veel netstroom → gas verwarmt, airco uit
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ do_heat and grid_high }}"
|
||
sequence:
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "off"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input tado_climate
|
||
data:
|
||
temperature: "{{ _target }}"
|
||
|
||
# ── KOELEN ────────────────────────────────────────────────────────────────
|
||
|
||
# K1: Koelen met zonne-overschot → airco koel modus
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ do_cool and solar_cool_ok }}"
|
||
sequence:
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input tado_climate
|
||
data:
|
||
temperature: "{{ _tado_off }}"
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "cool"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
temperature: "{{ _target }}"
|
||
|
||
# K2: Koelen zonder overschot maar netstroom toegestaan
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ do_cool and not solar_cool_ok and grid_cool_ok }}"
|
||
sequence:
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input tado_climate
|
||
data:
|
||
temperature: "{{ _tado_off }}"
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "cool"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
temperature: "{{ _target }}"
|
||
|
||
# K3: Koelen gewenst maar te duur / uitgeschakeld → airco uit, wachten
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ do_cool and not solar_cool_ok and not grid_cool_ok }}"
|
||
sequence:
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "off"
|
||
|
||
# ── DOELTEMPERATUUR BEREIKT → alles op minimum ────────────────────────────
|
||
- conditions:
|
||
- condition: template
|
||
value_template: "{{ at_target }}"
|
||
sequence:
|
||
- service: climate.set_hvac_mode
|
||
target:
|
||
entity_id: !input airco_climate
|
||
data:
|
||
hvac_mode: "off"
|
||
- service: climate.set_temperature
|
||
target:
|
||
entity_id: !input tado_climate
|
||
data:
|
||
temperature: "{{ _tado_off }}" |